{"product_id":"flexitec-2020-adhesion-test-kit","title":"Flexitec 2020 Adhesion Test Kit","description":"\u003ch3 data-start=\"444\" data-end=\"500\"\u003eCheck If Flexitec 2020 Will Stick Before You Install\u003c\/h3\u003e\n\u003cp data-start=\"502\" data-end=\"681\"\u003eThe Flexitec Adhesion Test Kit is used to check whether the \u003cstrong\u003e\u003ca href=\"collections\/flexitec\"\u003eFlexitec 2020 GRP roofing system\u003c\/a\u003e\u003c\/strong\u003e will properly bond to an existing roof surface before you install the full system.\u003c\/p\u003e\n\u003cp data-start=\"683\" data-end=\"831\"\u003eIt’s especially important when installing over PVC single-ply membranes, EPDM, or existing liquid roofing systems, where adhesion can’t be assumed.\u003c\/p\u003e\n\u003ch2 data-start=\"838\" data-end=\"880\"\u003eWhy You Should Use an Adhesion Test Kit\u003c\/h2\u003e\n\u003cp data-start=\"882\" data-end=\"994\"\u003eNot every roof is suitable for over-coating. Some surfaces look fine but won’t allow the resin to bond properly. Some require a combination of components based on the results of the adhesion test.\u003c\/p\u003e\n\u003cp data-start=\"996\" data-end=\"1153\"\u003eThis kit lets you test adhesion first, so you know whether Flexitec 2020 is suitable for your roof before spending time and money on a full installation. It also helps you determine the right components you need for the best possible adhesion.\u003c\/p\u003e\n\u003cp data-start=\"1155\" data-end=\"1234\"\u003eIf the test patch can’t be removed once cured, the surface is suitable to coat.\u003c\/p\u003e\n\u003ch2 data-start=\"1241\" data-end=\"1267\"\u003eWhen This Kit Is Needed\u003c\/h2\u003e\n\u003cp data-start=\"1269\" data-end=\"1320\"\u003eYou should use the Flexitec Adhesion Test Kit when:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-start=\"1324\" data-end=\"1356\"\u003eCoating PVC single-ply roofs\u003c\/li\u003e\n\u003cli data-start=\"1359\" data-end=\"1385\"\u003eCoating EPDM membranes\u003c\/li\u003e\n\u003cli data-start=\"1388\" data-end=\"1431\"\u003eCoating existing liquid-applied roofing\u003c\/li\u003e\n\u003cli data-start=\"1434\" data-end=\"1482\"\u003eYou’re unsure what the existing roof covering is\u003c\/li\u003e\n\u003cli data-start=\"1485\" data-end=\"1544\"\u003eYou’re planning an overlay rather than a full strip-off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1546\" data-end=\"1624\"\u003eThis follows the Flexitec application guidance and helps avoid problems later.\u003c\/p\u003e\n\u003ch2 data-end=\"1670\" data-start=\"1631\"\u003eHow the Test Works (Simple Overview)\u003c\/h2\u003e\n\u003col\u003e\n\u003cli data-end=\"1712\" data-start=\"1675\"\u003eClean and prepare a small test area\u003c\/li\u003e\n\u003cli data-end=\"1745\" data-start=\"1716\"\u003eApply primer where required\u003c\/li\u003e\n\u003cli data-end=\"1798\" data-start=\"1749\"\u003eInstall a small reinforced Flexitec resin patch\u003c\/li\u003e\n\u003cli data-end=\"1826\" data-start=\"1802\"\u003eAllow it to fully cure\u003c\/li\u003e\n\u003cli data-end=\"1882\" data-start=\"1830\"\u003eTry to remove the patch after the recommended time\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-end=\"1977\" data-start=\"1884\"\u003eIf the patch is firmly bonded and won’t lift, Flexitec 2020 can be installed on that surface.\u003c\/p\u003e\n\u003ch2 data-end=\"2013\" data-start=\"1984\"\u003eWhat’s Included in the Kit\u003c\/h2\u003e\n\u003cp data-end=\"2109\" data-start=\"2015\"\u003eThe kit contains everything you need to carry out a proper test using real Flexitec materials:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"2138\" data-start=\"2113\"\u003eFlexitec 2020 Resin\u003c\/li\u003e\n\u003cli data-end=\"2162\" data-start=\"2141\"\u003eFlexitec Primer\u003c\/li\u003e\n\u003cli data-end=\"2195\" data-start=\"2165\"\u003eFlexitec Powder Hardener\u003c\/li\u003e\n\u003cli data-end=\"2225\" data-start=\"2198\"\u003e225g Fibreglass Matting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2296\" data-start=\"2227\"\u003eUsing the actual system components means the test result is reliable.\u003c\/p\u003e\n\u003ch2 data-end=\"2318\" data-start=\"2303\"\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli data-end=\"2378\" data-start=\"2322\"\u003eConfirms whether Flexitec 2020 will stick to your roof\u003c\/li\u003e\n\u003cli data-end=\"2422\" data-start=\"2381\"\u003eRemoves guesswork on refurbishment jobs\u003c\/li\u003e\n\u003cli data-end=\"2459\" data-start=\"2425\"\u003eHelps avoid failed installations\u003c\/li\u003e\n\u003cli data-end=\"2496\" data-start=\"2462\"\u003eSaves time, labour and materials\u003c\/li\u003e\n\u003cli data-end=\"2545\" data-start=\"2499\"\u003eSuitable for roofers and competent DIY users\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-end=\"2570\" data-start=\"2552\"\u003eA Roofer’s Take\u003c\/h2\u003e\n\u003cp data-end=\"2746\" data-start=\"2572\"\u003eOverlay jobs are where problems usually start if you don’t test first. The Flexitec Adhesion Test Kit gives you a clear yes-or-no answer before you commit to the full system.\u003c\/p\u003e\n\u003cp data-end=\"2844\" data-start=\"2748\"\u003eIf you’re working over an existing membrane or coating, this kit is the sensible first step.\u003c\/p\u003e","brand":"The Flat Roofing Shop","offers":[{"title":"Default Title","offer_id":56326775308619,"sku":"FT-Test-Kit","price":18.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4054\/9451\/files\/Flexitec-adhesion-kit.jpg?v=1774701603","url":"https:\/\/theflatroofingshop.co.uk\/products\/flexitec-2020-adhesion-test-kit","provider":"The Flat Roofing Shop","version":"1.0","type":"link"}