{"product_id":"grp-deck-temperature-laser-thermometer","title":"GRP Roofing Deck Temperature Laser Thermometer","description":"\u003ch3\u003eInfrared Surface Thermometer for Accurate Catalyst Control\u003c\/h3\u003e\n\n\u003cp\u003eThis \u003cstrong\u003edeck temperature laser thermometer\u003c\/strong\u003e is an essential tool for GRP roofing installations. It allows you to quickly measure the \u003cstrong\u003eactual surface temperature of the deck\u003c\/strong\u003e before applying resin.\u003c\/p\u003e\n\n\u003cp\u003eIn fibreglass systems such as GRP Roof and Flexitec, catalyst and hardener ratios are determined by temperature. Ambient air temperature is often misleading - the deck surface can be significantly warmer or colder depending on sunlight, wind and time of day.\u003c\/p\u003e\n\n\u003cp\u003eUsing a laser thermometer ensures you mix resin accurately and avoid under or over-catalysing.\u003c\/p\u003e\n\n\u003cdetails style=\"margin-bottom:12px; border:1px solid #333; border-radius:10px; background:#1a1a1a; overflow:hidden;\"\u003e\n  \u003csummary style=\"cursor:pointer; font-weight:700; padding:16px 48px 16px 16px; font-size:18px; position:relative;\"\u003e\n    What It’s Used For\n    \u003cspan style=\"position:absolute; right:16px; top:50%; transform:translateY(-50%);\"\u003e▸\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cdiv style=\"padding:16px; border-top:1px solid #333;\"\u003e\n    \u003cul\u003e\n      \u003cli\u003eMeasuring deck temperature prior to GRP application\u003c\/li\u003e\n      \u003cli\u003eDetermining correct catalyst or hardener percentage\u003c\/li\u003e\n      \u003cli\u003eConfirming working conditions in cold or hot weather\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003eIdeal for use with GRP, Flexitec and other resin-based roofing systems.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:12px; border:1px solid #333; border-radius:10px; background:#1a1a1a; overflow:hidden;\"\u003e\n  \u003csummary style=\"cursor:pointer; font-weight:700; padding:16px 48px 16px 16px; font-size:18px; position:relative;\"\u003e\n    Why It Matters\n    \u003cspan style=\"position:absolute; right:16px; top:50%; transform:translateY(-50%);\"\u003e▸\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cdiv style=\"padding:16px; border-top:1px solid #333;\"\u003e\n    \u003cp\u003eIncorrect catalyst ratios can lead to:\u003c\/p\u003e\n    \u003cul\u003e\n      \u003cli\u003eResin curing too quickly\u003c\/li\u003e\n      \u003cli\u003eResin remaining soft or tacky\u003c\/li\u003e\n      \u003cli\u003eReduced laminate performance\u003c\/li\u003e\n      \u003cli\u003eWasted materials\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003eA surface temperature reading allows you to refer directly to your system’s catalyst chart and mix accurately for the conditions on site.\u003c\/p\u003e\n    \u003cp\u003eIt’s a simple step that prevents costly mistakes.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:12px; border:1px solid #333; border-radius:10px; background:#1a1a1a; overflow:hidden;\"\u003e\n  \u003csummary style=\"cursor:pointer; font-weight:700; padding:16px 48px 16px 16px; font-size:18px; position:relative;\"\u003e\n    How It Works\n    \u003cspan style=\"position:absolute; right:16px; top:50%; transform:translateY(-50%);\"\u003e▸\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cdiv style=\"padding:16px; border-top:1px solid #333;\"\u003e\n    \u003cul\u003e\n      \u003cli\u003ePoint the laser at the deck surface\u003c\/li\u003e\n      \u003cli\u003ePush the button\u003c\/li\u003e\n      \u003cli\u003eRead the temperature instantly\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003eNo contact is required, making it safe and fast to use across large roof areas.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:12px; border:1px solid #333; border-radius:10px; background:#1a1a1a; overflow:hidden;\"\u003e\n  \u003csummary style=\"cursor:pointer; font-weight:700; padding:16px 48px 16px 16px; font-size:18px; position:relative;\"\u003e\n    Technical Specification\n    \u003cspan style=\"position:absolute; right:16px; top:50%; transform:translateY(-50%);\"\u003e▸\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cdiv style=\"padding:16px; border-top:1px solid #333;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -9°C to +199°C\u003cbr\u003e\n    \u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1°C\u003cbr\u003e\n    \u003cstrong\u003ePower Supply:\u003c\/strong\u003e 2 x 1.5V AAA batteries\u003cbr\u003e\n    \u003cstrong\u003eBattery Life:\u003c\/strong\u003e Approx. 20 hours\u003cbr\u003e\n    \u003cstrong\u003eType:\u003c\/strong\u003e Non-contact infrared thermometer\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cdetails style=\"margin-bottom:12px; border:1px solid #333; border-radius:10px; background:#1a1a1a; overflow:hidden;\"\u003e\n  \u003csummary style=\"cursor:pointer; font-weight:700; padding:16px 48px 16px 16px; font-size:18px; position:relative;\"\u003e\n    Roofer’s Perspective\n    \u003cspan style=\"position:absolute; right:16px; top:50%; transform:translateY(-50%);\"\u003e▸\u003c\/span\u003e\n  \u003c\/summary\u003e\n  \u003cdiv style=\"padding:16px; border-top:1px solid #333;\"\u003e\n    \u003cp\u003eAir temperature means nothing if the deck’s been sitting in sun or frost. A quick surface check before you mix resin takes seconds and saves a lot of problems later.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/details\u003e","brand":"The Flat Roofing Shop","offers":[{"title":"Default Title","offer_id":56659314803019,"sku":"FT-Laser-Thermometer","price":31.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0997\/4054\/9451\/files\/laser-thermometer.jpg?v=1774107676","url":"https:\/\/theflatroofingshop.co.uk\/products\/grp-deck-temperature-laser-thermometer","provider":"The Flat Roofing Shop","version":"1.0","type":"link"}